Retrieving the COM Class Factory Error
While attempting to upgrade Verify Privilege Manager, you receive an error message when accessing
https://[YourInstanceName]/TMS/Setup
.
The window is unable to load with the following error message:
“Server Error in '/Tms/Setup' Application.
Retrieving the COM class factory for component with CLSID {228FB8F7-FB53-4FD5-8C7B-FF59DE606C5B} failed due to the following error:
800703fa Illegal operation attempted on a registry key that has been marked for deletion. (Exception from HRESULT: 0x800703FA).”
Resolve
-
Close the browser window.
-
Complete an IIS reset by searching for the Windows PowerShell application.
-
Right-click and select Run as Administrator.
-
Enter: IISreset |. Press Enter.
-
Once the IIS reset has completed navigate back to
https://[YourInstanceName]/TMS/Setup
. -
Click Add / Update Product Features.
-
Click Install/Upgrade Products.
-
Select ALL required solutions.
-
Click Install and the upgrade process will begin.